$ DeviceNet Electronic Data Sheet for 1782-JDM $ $ Tested against: EDSChecker, version 2.12, 8/6/01 $ $ EDS Version 2.03, 8/10/01, FJB - updated Param 8 and 10 to SHORT STRING length = 1 [File] DescText = "1782-JDM EDS"; CreateDate = 05-05-2000; CreateTime = 17:00:00; ModDate = 08-06-2001; ModTime = 11:06:45; Revision = 2.03; [Device] VendCode = 9; $ Vendor Code VendName = "WRC - Western Reserve Controls, Inc."; ProdType = 0x0C; $ Product Type ProdTypeStr = "Communications Adapter"; ProdCode = 711; $ Product Code MajRev = 2; $ Major Rev MinRev = 03; $ Minor Rev ProdName = "1782-JDM"; Catalog = "1782-JDM"; [IO_Info] Default = 0x0001; $Default to polled connection PollInfo = 0x0001,1,1; $Poll can be allocated with all cnxn Input1= 51, $ produce connection size 0, $ 0 = all bits significant 0x0001, $ use for POLL connection "JDM Poll Response", $ name string 6, $ connection path size in bytes "20 04 24 03 30 03", $ connection path "Number of bytes returned to Master: Counter & Status & Modbus data & CR/LF "; $ help string Output1= 50, $ consume connection size 0, $ 0 = all bits significant 0x0001, $ use for POLL connection "JDM Poll Command", $ name string 6, $ connection path size in bytes "20 04 24 03 30 03", "Number of bytes received from Master: Status & Modbus data & Counter & CR/LF "; $ help string [ParamClass] MaxInst=11; Descriptor=9; $ support param instances, params stored in NV CfgAssembly=0; [Params] Param1 = 0, 6,"20 0F 24 01 30 01", $ class 15, this param instance, attr 1 0x02, $ enumerated values 8,1, $8-bit byte "Modbus Protocol", "", $No Units "ASCII or RTU Modbus Protocol", 0,1,0, , , , , , , , , ; $Unused params fields 13-21 Param2 = 0, 6,"20 0F 24 02 30 01", $ class 15, inst. 2, att 1 0x00, $ no enumerated values 8,1, $ 8-bit byte "Rx Character Length", "", "Max Number of bytes of data received from the Modbus device", 1,100,48, , , , , , , , , ; $Unused params fields 13-21 Param3 = 0, 6,"20 0F 24 03 30 01", $class 15, inst. 3, att 1 0x00, $ no enumerated values 8,1, $8 bit byte "Tx Character Length", "", "Max Number of bytes of data transmitted to the Modbus device", 1,100,48, , , , , , , , , ; $Unused params fields 13-21 Param4 = 0, 6,"20 0F 24 04 30 01", $class 15, inst. 4, att 1 0x02, $ enumerated values 8,1, $8 bit byte "Modbus Baudrate", "Baud", "Modbus Link Baudrate: 9600 (default), 1200, 2400, 4800, 9600, 19.2k, 38.4k", 0,5,0, , , , , , , , , ; $Unused params fields 13-21 Param5 = 0, 6,"20 0F 24 05 30 01", $class 15, inst. 5, att 1 0x02, $ enumerated values 8,1, $8 bit byte "DeviceNet Baudrate", "Baud", "DeviceNet Baudrate: 125k, 250k, 500k, Autobaud (default)", 0,3,3, , , , , , , , , ; $Unused params fields 13-21 Param6 = 0, 6,"20 0F 24 06 30 01", $class 15, inst. 6, att 1 0x00, $ no enumerated values 2,2, $8 bit byte "Modbus Time-out", "1ms ticks", "Modbus response wait time (1 ms ticks) before fault (0=none)", 0,65535,0, , , , , , , , , ; $Unused params fields 13-21 Param7 = 0,6,"20 0F 24 07 30 01", $class 15, inst. 7, att 1 0x02, $ enumerated values 8,1, $8 bit byte "Fault action", "", "Action to take if a DeviceNet fault occurs", 0, 1, 0, , , , , , , , , ; $Unused params fields 13-21 Param8 = 0, 6,"20 0F 24 08 30 01", $ class 15, inst. 2, att 1 0x00, $ no enumerated values 23,1, $ short string, 1 char per new ODVA spec "Fault string", "", "String sent to Modbus device after fault (if fault action = 1)", , , , , , , , , , , , ; $Unused params fields 10-21 Param9 = 0, 6,"20 0F 24 09 30 01", $class 15, inst. 2, att 1 0x02, $ enumerated values 8,1, $8 bit byte "Idle action", "", "Action to take if a DNet idle command is sent to JDM", 0, 1, 0, , , , , , , , , ; $Unused params fields 13-21 Param10 = 0, 6,"20 0F 24 0A 30 01", $class 15, inst. 2, att 1 0x00, 23,1, $ short string, 1 char per new ODVA spec "Idle string", "", "String sent to Modbus device upon DNet Idle cmd (if idle action=1)", , , , , , , , , , , , ; $Unused params fields 10-21 Param11 = 0, 6,"20 0F 24 0B 30 01", $class 15, inst. 2, att 1 0x02, $ enumerated values 8,1, $8 bit byte "Serial Comm Format", "", "Serial link framing data: data bits, parity, stop bits", 0, 6, 0, , , , , , , , , ; $Unused params fields 13-21 [EnumPar] Param1 = "ASCII Mode", "RTU Mode"; Param4 = "9600", "1200", "2400", "4800", "19.2k", "38.4k"; Param5 = "125k", "250k", "500k", "Autobaud"; Param7 = "No action upon fault", "Send defined string to Modbus device upon fault"; Param9 = "No action upon Idle Command", "Send defined string to Modbus device upon Idle Command"; Param11 = "7 data bits, No parity, 2 stop bits", "7 data bits, Even parity, 1 stop bit", "7 data bits, Odd parity, 1 stop bit", "8 data bits, No parity, 1 stop bit", "8 data bits, No parity, 2 stop bits", "8 data bits, Even parity, 1 stop bit", "8 data bits, Odd parity, 1 stop bit"; [Groups] Group1 = "ModBus Link", 6, 1, 2, 3, 4, 6, 11; Group2 = "DeviceNet Link", 5, 5, 7, 8, 9, 10;