$ DeviceNet Electronic Data Sheet for 1782-JDM $ $ $ Tested against: EDSChecker, version 2.02, 7/2/2000 [File] DescText = "1782-JDM EDS"; CreateDate = 05-05-2000; CreateTime = 17:00:00; ModDate = 07-03-2000; ModTime = 17:27:00; Revision = 1.00; [Device] VendCode = 9; $ Vendor Code VendName = "WRC - Western Reserve Controls, Inc."; ProdType = 0x0C; $ Product Type ProdTypeStr = "Communications Adapter"; ProdCode = 711; $ Product Code MajRev = 1; $ Major Rev MinRev = 01; $ Minor Rev ProdName = "1782-JDM"; $ Catalog = "1782-JDM"; [IO_Info] Default = 0x0001; $Default to polled connection PollInfo = 0x0001,1,1; $Poll can be allocated with all cnxn Input1= 11, $ connection size: 6 bytes (mb addr, <=10 data value words) 0, $ 0 = all bits significant 0x0001, $ POLL connection "JDC-DELTA Poll Input", 6, $ connection path size in bytes "20 4 24 3 30 3", $ connection path "Return all selected VFD 21xx Registers data "; Output1= 5, $ connection size: 6 bytes (mb addr, data addr word, data value word) 8, 0x0001, "JDM Poll Output", 6, $ connection path size in bytes "20 4 24 3 30 3", "Send output value to specified VFD register"; [ParamClass] MaxInst=11; Descriptor=9; CfgAssembly=0; [Params] Param1 = 0, 6,"20 15 24 1 30 1", $class 15, inst. 1, att 1 $ MUST UPDATE THIS FIELD 0x02, $ MUST UPDATE THIS FIELD 24,1, $8-bit byte "Modbus Protocol", "", $No Units "ASCII or RTU Modbus Protocol", 0,1,0, , , , , , , , , ; $Unused params fields 13-21 Param2 = 0, 6,"20 15 24 2 30 1", $class 15, inst. 2, att 1 $ MUST UPDATE THIS FIELD 0x00, 24,1, $8 bit byte "Rx Character Length", "", "Max Number of bytes of data received from the Modbus device", 1,96,48, , , , , , , , , ; $Unused params fields 13-21 Param3 = 0, 6,"20 15 24 3 30 1", $class 15, inst. 2, att 1 $ MUST UPDATE THIS FIELD 0x00, 24,1, $8 bit byte "Tx Character Length", "", "Max Number of bytes of data transmitted to the Modbus device", 1,96,48, , , , , , , , , ; $Unused params fields 13-21 Param4 = 0, 6,"20 15 24 2 30 1", $class 15, inst. 2, att 1 $ MUST UPDATE THIS FIELD 0x02, $ MUST UPDATE THIS FIELD 24,1, $8 bit byte "Baudrate", "", "Modbus Link Baudrate", 0,7,0, , , , , , , , , ; $Unused params fields 13-21 Param5 = $Not currently implemented 0, 6,"20 15 24 3 30 1", $class 15, inst. 2, att 1 $ MUST UPDATE THIS FIELD 0x02, $ MUST UPDATE THIS FIELD 24,1, $8 bit byte "DeviceNet Baud Rate", "", "DeviceNet Baud Rate - 3 = autobaud (default)", 0,3,3, , , , , , , , , ; $Unused params fields 13-21 Param6 = 0, 6,"20 15 24 4 30 1", $class 15, inst. 2, att 1 $ MUST UPDATE THIS FIELD 0x00, $ MUST UPDATE THIS FIELD 24,1, $8 bit byte "Modbus Time-out", "10ms", "Modbus response wait time (10ms ticks) before fault (0=none)", 0,255,0, , , , , , , , , ; $Unused params fields 13-21 Param7 = $Not currently implemented 0, 6,"20 15 24 5 30 1", $class 15, inst. 2, att 1 $ MUST UPDATE THIS FIELD 0x02, $ MUST UPDATE THIS FIELD 24,1, $8 bit byte "Fault action", "", "Action to take if a DeviceNet fault occurs", 0, 1, 0, , , , , , , , , ; $Unused params fields 13-21 Param8 = $Not currently implemented 0, 6,"20 15 24 6 30 1", $class 15, inst. 2, att 1 $ MUST UPDATE THIS FIELD 0x00, $ MUST UPDATE THIS FIELD 24,1, $8 bit byte "Fault string", "", "String sent to Drive after fault (if fault action = 1)", , , , , , , , , ; $Unused params fields 13-21 Param9 = $Not currently implemented 0, 6,"20 15 24 7 30 1", $class 15, inst. 2, att 1 $ MUST UPDATE THIS FIELD 0x02, $ MUST UPDATE THIS FIELD 24,1, $8 bit byte "Idle action", "", "Action to take if a DNet idle command is sent to JDM", 0, 1, 0, , , , , , , , , ; $Unused params fields 13-21 Param10 = $Not currently implemented 0, 6,"20 15 24 8 30 1", $class 15, inst. 2, att 1 $ MUST UPDATE THIS FIELD 0x00, $ MUST UPDATE THIS FIELD 24,1, $8 bit byte "Idle string", "", "String sent Drive upon DNet Idle cmd (if idle action=1)", , , , , , , , , ; $Unused params fields 13-21 Param11 = $Not currently implemented 0, 6,"20 15 24 9 30 1", $class 15, inst. 2, att 1 $ MUST UPDATE THIS FIELD 0x02, $ MUST UPDATE THIS FIELD 24,1, $8 bit byte "Serial Comm Format", "", "Serial link framing data: data bits, parity, stop bits", 0, 5, 0, , , , , , , , , ; $Unused params fields 13-21 [EnumPar] Param1 = "ASCII Mode", "RTU Mode"; Param4 = "9600 baud", "300 baud", "600 baud", "1200 baud", "2400 baud", "4800 baud", "19.2k baud", "38.4k baud"; Param5 = "125k baud", "250k baud", "500k baud", "Autobaud"; Param7 = "No action upon fault", "Send defined string to Drive upon fault"; Param9 = "No action upon Idle Command", "Send defined string to Drive upon Idle Command"; Param11 = "7 data bits, No parity, 2 stop bits", "7 data bits, Odd parity, 1 stop bit", "7 data bits, Even parity, 1 stop bit", "8 data bits, No parity, 2 stop bits", "8 data bits, Odd parity, 1 stop bit", "8 data bits, Even parity, 1 stop bit"; [Groups]